Radiological union analysis of femoral shaft aseptic nonunion after failed plate and screw convert to reaming intramedullary solid locking nail

Abstract

Background: Non-united fracture shaft of the femur after plate fixation is a common problem. Management of this problem is still controversial. There are many methods for treating femoral shaft aseptic nonunions with a broken implant which conversion to reaming solid intramedullary nail is one of the procedures. However, the reported success rate varies. This study aimed to evaluate bone healing, especially callus formation, radiologically after nonunion reconstruction using intramedullary nailing reaming

Method: This study is a cross-sectional retrospective case analysis presenting 22 patients with the patient's age was 15 to 50 years old who underwent operation procedures managed by removing the hardware and converting to reaming solid intramedullary locking nail with or without autogenous iliac bone graft for at least six months. The bone healing process was assessed by serial plain radiography every six weeks using the Callus Index method.

Results: Conversion to reaming solid intramedullary nailing after nonunion with broken implant gives union rate 95%. Among 22 patients, one patient persisted in nonunion, and two patients experience delayed union. The Callus index of Fracture location (P=0,043)      significantly affected index callus formation (P<0.05); The fracture location, whereas fracture classification (P=0,365), nonunion type (P=0,398), and bone graft (P=0,510) did not significantly affect index callus formation (P>0.05). There was no significant difference in time to the solid union between patients with or without iliac autogenous bone graft. Proximal third nonunion affects the time to solid union. No significant complications were noted.

Conclusion: Nonunion reconstruction using solid reaming nail at both types nonunion gives a solid union. Solid union achieves with or without bone graft.

References

  1. Museru LM, Mcharo CN. The dilemma of fracture treatment in developing countries. Int Orthop. 2002;26(6):324–7. Available from: https://pubmed.ncbi.nlm.nih.gov/12466862
  2. Brumback RJ, Uwagie-Ero S, Lakatos RP, Poka A, Bathon GH, Burgess AR. Intramedullary nailing of femoral shaft fractures. Part II. J Bone Jt Surg. 1988;70(10):1453–62. Available from: http://dx.doi.org/10.2106/00004623-198870100-00003
  3. Thompson F, O’Beirne J, Gallagher J, Sheehan J, Quinlan W. Fractures of the femoral shaft treated by plating. Injury. 1985;16(8):535–8. Available from: http://dx.doi.org/10.1016/0020-1383(85)90079-8
  4. Ring D, Jupiter JB, Sanders RA, Quintero J, Santoro VM, Ganz R, et al. Complex Nonunion of Fractures of The Femoral Shaft Treated by Wave-Plate Osteosynthesis. J Bone Joint Surg Br. 1997;79-B(2):289–94. Available from: http://dx.doi.org/10.1302/0301-620x.79b2.0790289
  5. Klemm KW. Treatment of Infected Pseudarthrosis of the Femur and Tibia with an Interlocking Nail. Clin Orthop Relat Res. 1986;NA;(212):174-181. Available from: http://dx.doi.org/10.1097/00003086-198611000-00019
  6. Danckwardt-Lillieström G. Reaming of the Medullary Cavity and its Effect on Diaphyseal Bone: A Fluorochromic, Microangiographic and Histologic Study on the Rabbit Tibia and Dog Femur. Acta Orthop Scand. 1969;40(sup128):1–165. Available from: http://dx.doi.org/10.3109/ort.1969.40.suppl-128.01
  7. Aro HT, Chao EYS. Bone-Healing Patterns Affected by Loading, Fracture Fragment Stability, Fracture Type, and Fracture Site Compression. Clin Orthop Relat Res. 1993;NA;(293):8-17. Available from: http://dx.doi.org/10.1097/00003086-199308000-00003
  8. Naeem-ur-Razaq M, Qasim M, Sultan S. Exchange nailing for non-union of femoral shaft fractures. J Ayub Med Coll Abbottabad. 2010;22(3):106–9.
  9. Yu C-W, Wu C-C, Chen W-J. Aseptic nonunion of a femoral shaft treated using exchange nailing. Chang Gung Med J. 2002;25(9):591–8.
  10. Beredjiklian PK, Naranja RJ, Heppenstall RB, Brighton CT, Esterhai JL. Results of treatment of 111 patients with nonunion of femoral shaft fractures. Univ Pennsylvania Orthop J. 1999;12:52–6.
  11. Emara KM, Allam MF. Intramedullary Fixation of Failed Plated Femoral Diaphyseal Fractures: Are Bone Grafts Necessary? J Trauma Inj Infect Crit Care. 2008;65(3):692–7. Available from: http://dx.doi.org/10.1097/ta.0b013e31812f6dd9
  12. Brinker MR, O?Connor DP. Exchange Nailing of Ununited Fractures. J Bone Jt Surg. 2007;89(1):177–88. Available from: http://dx.doi.org/10.2106/jbjs.f.00742
  13. Wu CC, Shih CH, Chen WJ, Tai CL. Treatment of Ununited Femoral Shaft Fractures Associated With Locked Nail Breakage: Comparison Between Closed and Open Revision Techniques. J Orthop Trauma. 1999;13(7):494–500. Available from: http://dx.doi.org/10.1097/00005131-199909000-00006
  14. Wolinsky P, Tejwani N, Richmond JH, Koval KJ, Egol K, Stephen DJG. Controversies in Intramedullary Nailing of Femoral Shaft Fractures. J Bone Jt Surgery-American Vol. 2001;83(9):1404–15. Available from: http://dx.doi.org/10.2106/00004623-200109000-00018

How to Cite

Lengkong, A. C., Saleh, M. R., Yurianto, H., & Putra, L. T. (2021). Radiological union analysis of femoral shaft aseptic nonunion after failed plate and screw convert to reaming intramedullary solid locking nail. Bali Medical Journal, 10(2), 579–582. https://doi.org/10.15562/bmj.v10i2.2305

HTML
0

Total
15

Share

Search Panel

Andriessanto Ceelvin Lengkong
Google Scholar
Pubmed
BMJ Journal


M. Ruksal Saleh
Google Scholar
Pubmed
BMJ Journal


Henry Yurianto
Google Scholar
Pubmed
BMJ Journal


Luky Tandio Putra
Google Scholar
Pubmed
BMJ Journal